2000KVA Vertiv PowerNexus 【PowerNexus】
Mô tả
A 2000kVA Uninterruptible Power Supply (UPS) is a significantly larger power backup solution, designed for high-demand environments like large data centers, hospitals, manufacturing plants, or critical infrastructure facilities. With a capacity of 2000 kilovolt-amperes (kVA), it can handle substantial electrical loads, ensuring uninterrupted operation of sensitive or essential equipment during power disruptions.
In terms of real power, assuming a typical power factor of 0.8 to 1.0 (common for industrial-grade UPS systems), a 2000kVA UPS could deliver approximately 1600-2000kW, though exact output depends on the specific model and configuration. These units are often three-phase systems, operating at voltages like 400V or 480V, depending on regional standards and setup.
A UPS of this size typically includes advanced features:
Battery Backup: Provides immediate power during outages, with runtime varying based on battery size and load (often minutes to hours).
Scalability: Many are modular, allowing additional capacity or redundancy (e.g., N+1 configurations).
Efficiency: High-end models boast efficiencies above 95% in online double-conversion mode, minimizing energy waste.
Management: Remote monitoring, diagnostics, and integration with building management systems are standard.
Generator Compatibility: Often paired with diesel or gas generators for long-term backup.
Applications include protecting servers, telecom networks, or industrial machinery where downtime costs are astronomical. Such as the Vertiv Liebert EXL S1 with prices often exceeding hundreds of thousands of dollars, depending on customization.
Vertiv PowerNexus power system combines the robust power of Vertiv Trinergy and Vertiv Power Switchgear integrated in one single block connected by internal busbars. Such integration reduces equipment footprint, cabling materials, and installation labor costs.
The compactness of the Veriv PowerNexus solution enables data center industries to expedite IT deployment; specifically targeting hyperscale and colocation clients who are deploying power modules and power skids.
This not only aligns with their customers’ needs but also optimizes space, maximizing the capacity for income-generating IT equipment.
System can be pre-commissioned in the factory and delivered to the work site fully operational. Integrated EPMS (Energy & Power Monitoring System) is a standard feature.
There are three possible options:
On work site integration – Products designed for interconnection electrically, mechanically and digitally connected.
On skid integration – Products optimally arranged on a skid electrically, mechanically and digitally connected.
In enclosure integration – Products pre-integrated in an enclosure, electrically, mechanically and digitally connected.
Key features of Vertiv PowerNexus
– UPS with capacity up to 2500 kVA
– UPS power range: 1500, 2000,2500 kVA
– Switchgear with up to 5000A total load
– Two power inputs
– Direct and protected (UPS) outputs
– Integrated EPMS (optional)
– Robust, modular, and highly efficient UPS
– Safe and reliable power distribution technology
– Easy configurable single compact system
– No long run cables needed
– Predictive maintenance and distributed energy resources ready

Front-to-front: In this arrangement switchgear input section is connected to UPS and switchgear output section by busbars. This is suitable for on work site integration, on skid integration and in enclosure integration.
Technical Specifications 2000KVA UPS |
|
Vertiv PowerNexus 2000KVA | |
Rating [kVA] | 2000 |
Inputs | 2 (grid and generator) |
Operating temperature | Up to 35°C @ 100% load |
Relative humidity @ 20 °C (non condensing) | Up to 95% |
Frame colour (RAL scale) | RAL7021 |
IP protection | IP20 for UPS, IP31 for SWB |
Integration | Assembly on site or preassembled on skid or inclosure in factory |
Grounding | TN-C or TN-S |
Certification | CE and UL |
Nominal voltage [V] | 380, 400, 480 |
input breaker [A] | 4000 |
Short circuit rating | 100 kA/1s |
UPS | |
Core rating [kVA] | 500 |
Inventer Overload Capacity | 110% continuous, 125% for 10 mins, 150% for 1 min |
Input factor | ≥0.99 |
UPS modes | Online (VFI), Dynamic Online (VI), ECO Mode (VFD) |
UPS efficiency @ VFI mode | ≥97% |
UPS efficiency @ VFD mode | ≥99% |
Frequency range [Hz] | 40 – 70 |
UPS serviceability | Complete UPS isolation by using external bypass |
Battery voltage range [V] | 397 – 700 |
Ứng dụng của một UPS 2000kVA
Ứng dụng của một UPS 2000kVA rất đa dạng, chủ yếu phục vụ các môi trường đòi hỏi nguồn điện liên tục và ổn định với công suất lớn. Dưới đây là các ứng dụng chính của hệ thống UPS 2000kVA:
Trung tâm dữ liệu (Data Centers):
Bảo vệ các máy chủ, thiết bị lưu trữ và mạng khỏi mất điện đột ngột, đảm bảo dữ liệu không bị mất và dịch vụ trực tuyến hoạt động liên tục. Với công suất 2000kVA, nó có thể hỗ trợ các trung tâm dữ liệu quy mô lớn, nơi chứa hàng trăm hoặc hàng nghìn máy chủ.
Bệnh viện và cơ sở y tế:
Cung cấp điện cho các thiết bị y tế quan trọng như máy MRI, CT, phòng mổ, hoặc hệ thống hỗ trợ sự sống. Một UPS 2000kVA đảm bảo rằng các thiết bị này không bị gián đoạn, đặc biệt trong các tình huống khẩn cấp.
Nhà máy sản xuất và công nghiệp:
Giữ cho dây chuyền sản xuất, máy móc CNC, hoặc hệ thống điều khiển tự động hoạt động trơn tru, tránh thiệt hại do ngừng sản xuất đột ngột. Công suất lớn như 2000kVA phù hợp cho các nhà máy quy mô lớn với nhiều thiết bị nặng.
Hạ tầng viễn thông:
Duy trì hoạt động của các trạm phát sóng, trung tâm điều khiển mạng hoặc hệ thống liên lạc, đảm bảo kết nối không bị gián đoạn, đặc biệt trong các khu vực quan trọng như sân bay hoặc trung tâm chỉ huy.
Tòa nhà thương mại lớn:
Hỗ trợ các trung tâm thương mại, cao ốc văn phòng hoặc khách sạn lớn, nơi cần duy trì hệ thống chiếu sáng, thang máy, và các dịch vụ thiết yếu khác khi mất điện.
Hệ thống tài chính và ngân hàng:
Bảo vệ các máy chủ giao dịch, ATM, và hệ thống xử lý dữ liệu tài chính, nơi mà chỉ vài giây mất điện cũng có thể gây thiệt hại hàng triệu đô la.
Sự kiện và cơ sở hạ tầng công cộng:
Được sử dụng trong các sân vận động, trung tâm hội nghị hoặc hệ thống giao thông công cộng (như tàu điện), nơi cần nguồn điện ổn định để vận hành liên tục.
Với khả năng cung cấp công suất thực khoảng 1600-2000kW (tùy hệ số công suất), UPS 2000kVA thường được kết hợp với máy phát điện dự phòng để xử lý các sự cố kéo dài. Nó cũng phù hợp cho các hệ thống yêu cầu độ tin cậy cao (high availability) với cấu hình dự phòng như N+1.
Hãy đặt nền móng cho sự hợp tác bằng cách gọi cho tôi
(Mr Hoàng) Hotline: 0374585868
Website: VOIMT.COM
Huyen –
Inbox