20KVA UPS EXS0020kTH1AFN01000 【Liebert EXS】
Mô tả
Liebert EXS 20KVA
Compact design and improved performances
The new Liebert EXS is a monolithic transformer-free UPS which brings exceptional features for mission-critical applications. Its extraordinary double conversion efficiency up to 96.2% ensures remarkable operational cost savings, reducing both the Total Cost of Ownership (TCO) and the environmental impact.
At the same time, with its unity output power factor and high power density, Liebert EXS is able to provide the utmost active power possible in a compact footprint. In fact, its improved design reduces its footprint to a minimum, providing continuous power protection with optimized internal runtime in a standalone solution, making the Liebert EXS perfect for both IT installations and other mission critical applications, such as transportation, emergency lighting, healthcare, retail and government facilities.
Flexibility
To ensure superior protection for critical loads, the Liebert EXS range has been designed to optimize specific rating requirements, thus enhancing flexibility and installation space needs.
Liebert EXS’s flexibility is further enhanced through:
– Single and three phase output configurations up to 20 kVA
– Integrated parallel capability up to 4 units
– Common or distributed battery bank
– Internal and external battery configurations for optimized back up time management
– Casters for easy UPS repositioning
Output Configuration
Liebert EXS models up to 20 kVA can be configured on-site to deliver three (3/3) or single (3/1) phase output giving it the flexibility to adapt to changes in installation enviro
Technical Specifications UPS 20KVA model EXS0020kTH1AFN01000 |
|
Part Number | |
Model Number | EXS0020kTH1AFN01000 |
Ratings (kVA / kW ) | 20 |
Input | |
Nominal input voltage | 380 / 400 / 415 V (three -phase + N + PE) |
Input voltage range without battery discharge | 228 to 475 V* |
Nominal frequency | 50/ 60 Hz |
Input frequency range | 40 to 70 Hz |
Input power factor at full load | 0.99 kW/kVA |
Current THD at full linear load | ≤ 3 %* |
Bypass voltage tolerance | sele ctable from + 20 % to – 40 % |
Bypass frequency tolerance | ± 20 % (± 10 % selectable ) |
Battery | |
Battery blocks perstring | 24 to 40* |
Voltage temperature compensation | -3 .0 mV / °C / Cell |
Battery charger max. current | 12.5 A |
Output | |
Nominal output voltage | 380 / 400 / 415 V (three-phase + N + PE) or 220 / 230 / 240 V (single-phase + N + PE) |
Nominal output frequency | 50/ 60 Hz |
Maximum active power | 20 kW |
THDv at full linear load | 0.02 |
Inverter overload capacity | |
Double conversion | Up to 96.2 % |
ECO mode Dimensions and weight |
Up to 99 % |
Dimensions (WxDxH) | 335 x 650 x 1300 mm (standard version) 577 x 650 x 1300 mm (extended version) |
Net/ Shipping weight (excluding battery) | 85 / 115 kg (standard version) |
General | |
Noise at 1m | ≤58 dBA |
Maximum altitude | 1500 m without derating (max. 3000 m) |
Operating Temperature | up to 50 °C * |
Protection level IEC (60529) | IP20 |
General and safety requirements for UPS | EN/IEC/AS 62040 -1 |
EMC requirements for UPS | EN/IEC/A S 62040 -2 |
UPS classification according to IEC EN 62040-3 | VFI- SS-111 |