Chilled Water Perimeter Unit from 25 to 400 kW
Mô tả
Chilled Water
Chilled Water Perimeter Unit from 25 to 400 kW |
|||||||||||||
Vertiv Liebert PCW – Standard Height | PW025 | PW030 | PW035 | PW040 | PW045 | PW060 | PW070 | PW080 | PW095 | PW110 | PW145 | PW170 | |
Net Sensible Cooling Capacity Legacy Coil |
29 | 34.3 | 38.1 | 44 | 47.9 | 68.5 | 74.6 | 87.2 | 105.4 | 120.6 | 144 | 170.9 | |
Single Circuit Cooling Capacity | Net Sensible Cooling Capacity Smart Coil | – | 35.7 | – | 45.8 | – | 77.2 | – | 91.6 | – | 126 | 143 | 170.4 |
Net Sensible Cooling Capacity Eco Coil |
28.4 | – | 39.2 | – | 51.5 | 68 | 76.1 | – | 104.6 | – | – | – | |
Dual Circuit | Net Sensible Cooling Capacity kW | – | – | – | 35.3 | – | 52.7 | – | 63.7 | – | 87.2 | 99.7 | 119.3 |
Power input | kW | 1.39 | 1.83 | 1.45 | 1.69 | 1.56 | 2.85 | 2.67 | 3.63 | 4.2 | 5.37 | 6 | 7.39 |
Cooling Capacity |
|||||||||||||
Airflow Range [%] | m3/h | 2600 12000 |
2900 12000 |
3400 16000 |
3400 16000 |
5300 18000 |
5400 27000 |
6700 30400 |
7200 30000 |
9000 41000 |
10300 42000 |
12000 50000 |
13000 55000 |
Spare Capacity | % | 25 | 15 | 20 | 20 | 20 | 20 | 25 | 15 | 20 | 20 | 15 | 20 |
Dimension | |||||||||||||
Width | mm | 890 | 890 | 890 | 890 | 890 | 890 | 890 | 890 | 890 | 890 | 890 | 890 |
Unit Configuration | Down Flow UP Fans Over the Raised Floor | • | • | • | • | • | • | • | • | • | • | • | • |
Up Flow | • | • | • | • | • | • | • | • | • | • | |||
Frontal | • | • | • | • | • | • | • | • | • | • | |||
Downflow Down Fans in Raised Floor | • | • | • | • | • | • | • | • | • | • | • | • | |
Operating Modes Legacy – RAT 26°C 40% RH; Water I/O 10°C – 15°C; ESP 20Pa; Downflow Up; Fan Advance – HE Smart – RAT 35°C 30% RH; Water I/O 18°C – 26°C; ESP 20Pa; Downflow Up; EC Fan Advance – HE Eco – RAT 30°C 30% RH; Water I/O 8°C – 15°C; ESP 20Pa; Downflow Up; EC Fan Advance – HE |
Chilled Water Perimeter Unit from 25 to 400 kW | ||||||||
Vertiv Liebert PCW – Extended Height | PW046 | PW066 | PW091 | PW136 | PW161 | PW201 | PW400 | |
Single Circuit | Net Sensible Cooling Capacity kW | 49.4 | 75.9 | 95.9 | 134.9 | 164.3 | 206 | 400 |
Cooling Capacity | Net Sensible Cooling Capacity kW | 53.9 | 61.7 | 73.1 | 103.2 | 119.2 | 147.3 | 400 |
Dual Circuit Cooling Capacity | Net Sensible Cooling Capacity kW* | 39.9 | 61.7 | 73.1 | 103.2 | 119.2 | 147.3 | |
Power input | kW | 2.22 | 2.41 | 3.15 | 4.95 | 6.48 | 9.23 | 15.7 |
Airflow Range [%] | m3/h | 4600 – 18000 | 7600 – 31000 | 8300 – 33000 | 12000 – 47000 | 13000 – 50000 | 14600 – 61000 | 25000 -102000 |
Spare Capacity | % | 10 | 30 | 20 | 20 | 10 | 10 | 10 |
Legacy Coil | ||||||||
Smart Coil | ||||||||
Legacy Coil | ||||||||
Dimension |
Length | 1200 | 1750 | 2050 | 2550 | 2950 | 3350 | 3850 |
Width | 890 | 890 | 890 | 890 | 890 | 890 | 1780 | |
Height: Coil + Fan | 1970 + 600 | 1970 + 600 | 1970 + 600 | 1970 + 600 | 1970 + 600 | 1970 + 600 | 1970+750+750 | |
Unit Configuration | Filter Plenum | |||||||
Down Flow UP Fans Over the Raised Floor |
• | • | • | • | • | • | ||
Down Flow UP Frontal air Delivery |
• | • | • | • | • | • | ||
Down Flow UP Back air Delivery |
• | • | • | • | • | • | ||
UP Flow | • | • | • | |||||
Downflow Down Fans in Raised Floor |
• | • | • | • | • | • | • | |
Downflow Down Back air Delivery |
• | • | • | • | • | • |
Operating Modes
Legacy – RAT 26°C 40% RH; Water I/O 10°C – 15°C; ESP 20Pa; Downflow Up; Downflow Down for PW400; EC Fan Advance – HE
Smart – RAT 35°C 30% RH; Water I/O 18°C – 26°C; ESP 20Pa; Downflow Up; Downflow Down for PW400; EC Fan Advance – HE * with one circuit running