Mô tả

Vertiv Liebert ITA2 Three Phase UPS with Battery Flexibility (VRLA/Li-ion) 8kVA 208V/220V
Rack/Tower

Online Double-Conversion UPS offers the Highest level of Power Protection

The Liebert ITA2 is an online UPS designed to power three-phase (in/ out), 208/220V IT systems simply, reliably, and economically.
Key Benefits

– Optional lithium batteries

– Flexible placement. Use inside a rack or in a tower configuration

– Compact, high-power density

– Easy to install and manage

– High power factor maximizes the usable power

– Operates efficiently to save energy % and PF (Power Factor)

– Optimized maintenance bypass maintains power, even during servicing (optional)

– Extended battery runtimes available

– Flexible, easy to configure power distribution

Ideally Suited For Powering Many IT Systems

– IT closets, servers and more

– Branch, small-midsize IT systems

– Medical/lab testing equipment

– VoIP

– ISDN & frame relay applications

– Storage systems

– Security systems

– Light industrial

– Replacement for aging UPS

 

liebert ita2 ups 8KVA

High Performance and High Availability

– 1.0 Output Power Factor (PF): Provides more useable power enabling you to connect more equipment saving you money and space.

– Power Factor Correction: Prevents noise, harmonics, and distortion from being transferred to connected loads or fed back to the utility.

– Advanced Warning Status: Receive early audible and visual alarms warning you of system status to alert you to an input voltage, output overload, low battery, or battery replacement condition.

– Wide Input Voltage Range: Prolong battery life by allowing the UPS to maximize the use of the utility power before transferring to battery.

– Extended Runtime: VRLA (2U): Up to 5 strings (or 5 pairs of external battery cabinets) gives maximum runtime up to 67 min @ full load and 143 min at half. Lithium: Up to 8 strings (or 8 pairs of 1U external battery cabinets) give maximum runtime of 94 min at full load and 188 min at half load.

– High Efficiency: Operates up to 93% in normal (online) operating mode and up to 99% in Eco mode.

– Lightning and Surge Protection: The transient voltage surge suppression circuitry inside the Liebert ITA2 provides additional protection for the connected equipment.

Superior Battery Technology and Flexibility

– Hot-Swappable, User-Replaceable Batteries: Increase product life and reliability with both VRLA and
Li-ion batteries that can be easily replaced without disrupting power to connected equipment and minimize downtime.

– Safe and Reliable: Both VRLA and Li-ion ensure safety and reliability. Lithium-Ion (LiFePO4) battery chemistry is safest and integrated battery management system (BMS) also ensures safe and reliable operation.

– Environmentally Friendly: significantly reduce battery disposal and recycling with lower replacement rates.
[Refer to Vertiv Battery Recycling Program]

Lithium-Ion Batteries:

– Fewer Battery Replacements: Lithium-Ion batteries require fewer battery replacements and last on average up to 3 times as long as traditional VRLA batteries reducing maintenance, labor, and replacement costs (lower TCO).

– More Discharge Cycles: Lithium-Ion batteries deliver up to 10 times more charge / discharge cycles than VRLA batteries.

– Fast Recharge: Lithium-Ion batteries recharge twice as fast as traditional VRLA batteries getting you back to 90% in as little as 2 hours.

– Lighter Weight: Lithium-Ion batteries are 45% lighter making it ideal for smaller spaces and wall-mount racks.

Vertiv Liebert ITA2 UPS 8KVA

2U VRLA Battery Run Time Charts (8 and 10kVA)
Ups Model Battery String Qty 100% 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1
8kW 7.2kW 6.4kW 5.6kW 4.8kW 4kW 3.2kW 2.4kW 1.6kW 0.8kW
8kVA VRLA 1 13 15 18 21 26 33 40 56 101 166
2 33 36 40 49 61 76 102 135 167 345
3 52 61 71 82 103 126 147 167 314 650
4 76 91 103 121 137 152 181 227 347 870
5 103 112 130 143 156 181 219 318 540 1000
Liebert ita2 ups

 

Vertiv Liebert ITA2 UPS Specifications

ITEM 8KVA
Part Number ITA2-08KRT208C
Input 3 Phase Rated Voltage 208/220 VAC, 3 Phase, 4W+Gnd
Voltage Range 96VAC ~ 144VAC
Rated Frequency 60Hz
Frequency Range 40Hz~70Hz
Power Factor >0.99, at full load; >0.98, at half load
Output 3 Phase Rated Power    7.2kW                                                                     
Power Factor 0.9
Voltage  208/120VAC or 220/127VAC (3 Phase, 4W + Gnd)
Frequency Synchronization Range Rated frequency ± 3Hz. Configurable range: ±0.5 Hz~±5Hz
Frequency Track Rate 0.5Hz/s. Configurable range: 0.2/0.5/1Hz/s (single UPS), 0.2Hz/s (parallel system)
Crest Factor 3:1
Voltage Harmonic Distortion  <4% (linear load); <5% (non-linear load)
Dynamic Response Recovery Time 60ms
Overload Capacity     At 25˚C: 105% ~ 125%, 5 min; 125% ~ 150%, 1 min; 150%, 200ms
Bypass Voltage Upper Limit: +10% Lower Limit: -10%, -15%, -20%; default -10%
AC-AC Efficiency    Up to 93%

Battery liebert ita2 ups 8KVA

Type
Cell No. 192 by default
Rated Voltage 384VDC
Maximum Charge Current, A       <3.5A
Transfer Time Utility to Battery 1.8
Inverter to Bypass Synchronous Transfer: 0ms Asynchronous Transfer (default): ≤20ms or 40ms, 60ms, 80ms, 100ms and 200ms are available
Noise <55dB
Panel Display Mode Color LCD
Safety IEC/EN62040-1; UL/CSA, cULus (UL 1778 5th Edition, CSA No. 22.2 107.3)
EMC Conduction Emission IEC/EN62040-2
Harmonic Current IEC/EN61000-3-12
Surge Protection IEC/EN-61000-4-5, Endurance Level 4 (4kV) (live line to earth), Level 3 (2kV) (during live lines); ANSI C62.41, 6kV/20hms
Protection Level IP20
Ambient Condition Operating Temperature 32~122˚F (0~50˚C) (0.7 will be derated above 122˚F [50˚]
Storage Temperature 32 ~ 122°F (0 ~ 50°C), no derating
Relative Humidity 5%RH~ 95% RH, non-condensing
Altitude, ft. (m) Sea Level to 10,000 ft. (3000m) without derating
Dimensions, W x D x H, in. (mm) UPS 16.9 x 25.8 x 5.1 (430 x 656 x 130)
VRLA Battery Cabinet – ITA2-BCI0020K02 (Quantity of 2) 16.9 x 29.6 x 3.3 (430 x 751 x 85) per cabinet
1U Li-Ion Battery Cabinet – ITA2-BCI0020KL1 (Quantity of 2) 16.9 X 29.13 X 1.67 (430x740x42.5) per cabinet
2U Li-Ion Battery Cabinet – ITA2-BCI0020KL2 (Quantity of 2) 16.9 x 26.77 x 3.35 (430x680x85) per cabinet
Weight, lb. (kg) Maintenance Bypass Cabinet (MBC) 16.9 x 22.4 x 10.3 (430 x 570 x 261)
UPS Net: 50.7 (23)
Shipping: 70.5 (32)
VRLA Battery Cabinet Net: 115 (52.2) each Shipping: 306.4 (139)
1U Li-Ion Battery Cabinet Net: 44.09 (20)
Shipping: 165.3 (75)
2U Li-Ion Battery Cabinet Net: 70.5 (32) Shipping: 229.3 (104)
MBC Net: 39.7 (18.02)
Shipping: 59.5 (27)

👉 https://voimt.com/Hãy đặt nền móng cho sự hợp tác bằng cách gọi cho tôi 

(Mr Hoàng) Hotline: 0374585868 

Website: VOIMT.COM

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “Liebert ITA2 UPS 8KVA năm sản xuất 2024”

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *

0374585868
0388454589