UPS 750KVA

Liebert EXL S1 features a transformer- free design with full IGBT three-level double conversion technology, providing extraordinary savings on installation and running costs, while at the same time delivering first class load protection.
Liebert EXL S1 also features a full IGBT three-level rectifier allowing for electrical infrastructure cost saving, reducing the size of gensets, circuit protection, cabling and transformers.

Flexibility and Compatibility
Liebert EXL S1 can be fully adapted to meet diverse system requirements in terms of power capacity and redundancy allowing for different system designs, thus ensuring maximum flexibility:
– Output Power Factor up to 1
– No power derating from 0.4 lagging to 0.7 leading
– Optimum space/power ratio

UPS-750KVA
UPS-750KVA

 

Technical Specifications

UPS 750KVA
UPS Rating (kVA) 750
Output Active Power at 104°F (40°C) (kW) 750
Input AC Parameters
Input Voltage to Rectifier/ Bypass (VAC) 480, 3-phase, 3-wire
Permissible Input Voltage Range +10%, -15%
Input Frequency (Hz) 60 ± 5Hz
Input Power Factor ≥ 0.99
Input Current Distortion (THDi) at Nominal Voltage at Full Load (%) ≤ 3.0
Power Walk-in (seconds)  1 to 300 (selectable in 1 second increments)
Battery & DC Parameters
Battery Type
 Lithium ion, VRLA (Valve Regulated Lead Acid), VLA (Vented Lead Acid)
Nominal Battery Bus (VDC) / Battery Float Voltage (VDC) 480 / 540
DC Ripple at Float Voltage < 1.0% (RMS value) < 3.4% Vpp
Temperature Compensated Battery Charging  Standard with Vertiv Battery Cabinets
Output Parameters
Load Power Factor Supported (Without Derating) 0.7 Leading to 0.4 Lagging
Output Voltage (VAC) 480, 3-phase, 3-wire
Output Voltage Regulation (%) / Output Voltage Regulation < 1.0 (3-phase RMS average) / < 2.0 (3-phase RMS average) (50% Unbalanced Load) (%)
Output Frequency (Hz)  60 ± 0.1%
Output THD at Nominal Voltage (Linear Load) (%) ± 1.5 (RMS value)
Output THD at Nominal Voltage including a 100kVA Non Linear Load per IEC 6204-3 (%) ± 5.0 (RMS value)
Translent Recovery 100% Load Step / 50% Load Step / Loss of/Return to AC Input Power ±4% / ±2% / ±2% (RMS average for one cycle)
Voltage Displacement (Balance Loads) / Voltage Displacement (50% Balance Loads) 120 deg ±1 deg / 120 deg ±2 deg
Overload at Nominal Voltage and 77°F (25°C) 110% continuously, 125% for 10 minutes, 150% for 60 seconds, 200% for 200 miliseconds

Physical Characteristics

Dimensions with Standard I/O Cabinet, W x D x H 78.8 in x 36.0 in x 79.1 in
Dimensions with BFD or Sharing Inductor I/O Cabinet, W x D X H 109.4 in x 36.0 in x 79.1 in
Weight with Standard I/O Cabinet, Unpackaged 3508 lbs
Weight with BFD or Sharing Inductor I/O Cabinet, Unpackaged 5665 lbs (max)
Color Black, RAL 7021
Protection Class, UPS Enclosure NEMA 1, IP 20 (with and without front door open)
Environmental
Operating Temperature 32°F to 104°F (0°C to 40°C)
Relative Humidity 0% to 95%, non-condensing
Operating Altitude  Up to 3300 ft (1000 m) without derating
Communications
Options 2 Liebert Intellislots
Card Compatibility IS-UNITY-DP, IS-485EXI
Protocols Available MODBUS-IP, MODBUS-485, BACNET-IP, BACNET-MSTP, SNMP, HTTP, LIFE Services
Standards
Transportation / Safety ISTA Procedure 3B / UL 1778 5th Edition; CSA 22.2 NO 107.3
EMI / Surge IEC 62040-2; FCC Part 15, Class A / ANSI C624.41, Category B3
Seismic IBC 2015, CBC 2016, ASCE, OSHPD

👉 https://voimt.com/Hãy đặt nền móng cho sự hợp tác bằng cách gọi cho tôi

(Mr Hoàng) Hotline: 0374585868

Website: VOIMT.COM

3 đánh giá cho UPS 750KVA EXL S1 750KVA/750KW

  1. Tường Vy Sơn

    Giá thế nào em

  2. daihen

    Công suất lạ nhỉ

  3. Vãn Tình

    Công suất lớn nhỉ

Thêm đánh giá

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *

0374585868
0388454589